Single Leaf Lintel (TSSL)
Single leaf lintels are structural elements that are designed to carry the masonry load above openings, such as doors and windows. The lintels act as a horizontal beam distributing the load from across the opening maintaining the integrity and stability of masonry structures. Stainless Steel lintels should be installed with a minimum end bearing of 150mm either end and bedded into mortar and levelled along its length and across its width.
Lintel Types
Standard Lintel (L-Shape)
Predominately found in the external leaf, they are designed to be used in low load situations, typically small openings. S
Heavy Duty Lintel (C-Shape)
Predominately found in the external leaf they are designed to be used in high load capacities over small or large opening.
Our Accreditations
We hold a UK Certificate of conformity Factory Production Control to Harmonised Standard BS EN 1090-1:2009 +A1:2011 (Load bearing structural steel components up to EXC 2 according to BS EN 1090-2)
This certification covers our masonry support systems up to execution class 2 and therefore, we now offer a UKCA mark for these products in accordance with declaration method 3a.
We also hold a Gold level certification from Constructionline, this shows our commitement to ensuring all our onsite H&S procedures are up to the correct standard.